- GX-R System
For any robot and any task
With options for hollow and non-hollow wrists and a full range of torch necks, the GX-R system is easy to adapt to the needs of all robot MIG/MAG welding applications
Simply plugs-in and performs
The GX-R robot welding torch system is simple to integrate with any robot. It completes the Kemppi AX automated welding solution, ensuring your robot gets the best out of its Kemppi power source with every weld.
Precision and protection
The GX-R’s X-R Sensor helps any welding robot maintain the integrity of every weld and provides 360° protection from collisions, so your robot and products stay safe from damage.
The torch system your robot would choose
The GX-R robot welding torch system is built to plug in and perform in the most demanding automated MIG/MAG welding applications. Getting the best from your Kemppi AX welding power source, the GX-R system will meet the highest expectations of your robot and you.
The GX-R robot torch system is simple to integrate with hollow and non-hollow wrist robots from all leading brands. The wide range of swift-to-change necks allows the torch to be adapted to any task. And Kemppi’s long-lasting consumables minimize downtime and increase the robot welding torch’s lifecycle to maximize value.
The GX-R’s X-R Sensor gives your robot 360° protection from collisions and keeps your production schedule from being disrupted. The robot welding torch’s wire brake maintains optimal touch sense function in every position, ensuring consistent quality in each weld.
The GX-R robot welding torch system is always primed and ready by the automated cutting and cleaning station, and our unique neck-alignment tool ensures concentric accuracy of nozzle and wire. The GX-R robot torch system allows you to simply plug Kemppi’s welding know-how straight into your robots.
X-R Adapter T4 — Technical data
| Description | Value |
|---|---|
| Remote control | No |
| Weight | 300 g |
X-R Solid T3 — Technical data
| Description | Value |
|---|---|
| Remote control | No |
| Weight | 1000 g |
X-R Flange 50 - 6 - M6 #29 — Technical data
| Description | Value |
|---|---|
| Weight | 140 g |
X-R Flange 80 - 6 - M8 #30 — Technical data
| Description | Value |
|---|---|
| Weight | 360 g |
X-R Flange 56 - 6 - M4 #28 — Technical data
| Description | Value |
|---|---|
| Weight | 130 g |
GX-R Torch Adjuster W — Technical data
| Description | Value |
|---|---|
| Type of cooling | Liquid |
X-R Flange 56 - 8 - M4 #19 — Technical data
| Description | Value |
|---|---|
| Weight | 138 g |
X-R Flange 58 - 6 - M4 #22 — Technical data
| Description | Value |
|---|---|
| Weight | 116 g |
X-R Flange 31,5 - 4 - M5 #17 — Technical data
| Description | Value |
|---|---|
| Weight | 191 g |
X-R Flange 40 - 4 - M6 #15 — Technical data
| Description | Value |
|---|---|
| Weight | 202 g |
X-R Flange 31,5 - 4 - M5 #23 — Technical data
| Description | Value |
|---|---|
| Weight | 228 g |
GX-R Wire Brake G — Technical data
| Description | Value |
|---|---|
| Type of cooling | Air |
| Rating of electrical components (remote, nominal) | 24 V |
| Weight | 955 g |
X-R Flange 80 - 6 - M8 #12 — Technical data
| Description | Value |
|---|---|
| Weight | 207 g |
X-R Sensor T1 — Technical data
| Description | Value |
|---|---|
| Remote control | Yes |
| Rating of electrical components (remote, nominal) | 24 V |
| Rating of electrical components (remote, nominal) | 10 mA |
| Weight | 1306 g |
X-R Sensor T2 — Technical data
| Description | Value |
|---|---|
| Remote control | Yes |
| Rating of electrical components (remote, nominal) | 24 V |
| Rating of electrical components (remote, nominal) | 10 mA |
| Weight | 1457 g |
X-R Holder — Technical data
| Description | Value |
|---|---|
| Weight | 0.19 kg |
X-R Bracket M — Technical data
| Description | Value |
|---|---|
| Weight | 0.5 kg |
X-R Bracket S — Technical data
| Description | Value |
|---|---|
| Weight | 0.43 kg |
GX-R Wire Brake W — Technical data
| Description | Value |
|---|---|
| Type of cooling | Liquid |
| Rating of electrical components (remote, nominal) | 24 V |
| Weight | 902 g |
X-R Flange 63 - 4 - M6 #27 — Technical data
| Description | Value |
|---|---|
| Weight | 130 g |
X-R Flange 45 - 4 - M6 #25 — Technical data
| Description | Value |
|---|---|
| Weight | 201 g |
X-R Flange 40 - 4 - M6 #24 — Technical data
| Description | Value |
|---|---|
| Weight | 199 g |
X-R Flange 56 - 8 - M4 #21 — Technical data
| Description | Value |
|---|---|
| Weight | 138 g |
X-R Flange 36 - 6 - M4 #20 — Technical data
| Description | Value |
|---|---|
| Weight | 186 g |
X-R Flange 64 - 8 - M4 #18 — Technical data
| Description | Value |
|---|---|
| Weight | 134 g |
X-R Flange 100 - 6 - M10 #14 — Technical data
| Description | Value |
|---|---|
| Weight | 454 g |
X-R Flange 50 - 6 - M6 #13 — Technical data
| Description | Value |
|---|---|
| Weight | 210 g |
GX-R Torch Adjuster G — Technical data
| Description | Value |
|---|---|
| Type of cooling | Air |
GX-R Cable T1 S W 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1640mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1640mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 3500mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 3500mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1600mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1600mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1000mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1000mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1480mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1480mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 960mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1560mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1360mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 2160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1440mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1320mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1520mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 960mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1560mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1320mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1280mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 2240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 2160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1520mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1200mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1360mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1280mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 2240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1440mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1200mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 340mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 368 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 442.2 mm |
| Neck dimensions: height | 7.6 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 368 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 468 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 243.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 442.2 mm |
| Neck dimensions: height | 7.6 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 350.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 440mm 30D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 450.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 30 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 432.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 443.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 456.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 240mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 268 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 667 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 432.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 443.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 456.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 468 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 332.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 343.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 356.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 232.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 256.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 240mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 268 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 350.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 340mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 332.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 340mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 343.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 356.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 240mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 232.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 667 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W 240mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 243.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 667 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W 240mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 256.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 667 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 440mm 30D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 450.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 30 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |