Simply start welding
Designed for simplicity and ease of use, the X3 FastMig has a fast setup process and an icon-based user interface for streamlined parameter selection.
Work in tough conditions
With a robust design and durable wire feeder, the X3 FastMig was built for difficult jobs in the most challenging conditions. It looks tough, and it is.
Finish demanding jobs
With 420 or 450 amps at a 60% duty cycle, the X3 FastMig delivers powerful performance with high quality. Lock in on a task and keep going until it's done.
Brilliantly simple, brutally effective MIG/MAG welding
The X3 FastMig Synergic and Pulse MIG/MAG welding machines are the quickest way to complete high-quality welds in wide-ranging welding and fabrication environments. With a robust design and durable wire feeder, the X3 FastMig can handle the bumps and bangs of heavy industrial MIG/MAG welding. It looks tough, but it's also simple and precise. A new icon-based user interface saves time with a fast setup and easy parameter selection. The X3 FastMig gives you immediate control over key functions for a simple and reliable way to create high-quality welds.
It's a brilliantly simple MIG/MAG welder that is also extremely powerful. When tasks get tougher, the X3 FastMig is always ready to meet heavy production targets. Need to complete the biggest job on site? No problem. With 420 (X3S) or 450 amps (X3P) at a 60% duty cycle, the X3 is brutally effective without compromising on quality. Lock in on a task and keep going until it's done. The X3S and X3P FastMig are a perfect match for industrial welding where capable, accurate, and reliable welding equipment is essential and where MIG/MAG welder needs to support fast-changing and varying work tasks.
The X3 FastMig Synergic and Pulse models come with the X3 HD300 wire feeder, featuring a Duratorque 4x4 wire drive mechanism and a strong plastic case with dual-wall construction. The X3 HD300 wire feeder can be attached to the X3 FastMig's MIG/MAG power source with a rotating plate. The safe-lift design allows the wire feeder to be lifted and suspended by the handle. Add a 4-wheel trolley or do more by adding accessories like a hanger for boom for the HD300 wire feeder. Adjust parameters while welding with the HR53 hand remote or GRe50 torch remote control which are available as optional accessories.
Videos
X3 Wire Feeder HD200 Rotameter — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6.3 A |
| Idle power | 6 W |
| Welding current 60% | 450 A |
| Welding current 100% | 380 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 2 mm |
| Filler wire diameter, Al | 0.8 ... 2.4 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum wire spool weight | 5 kg |
| Maximum wire spool diameter | 200 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Control panel, display | LCD |
| Control panel, controls | 2 control knobs, Push buttons |
| Control panel, type of installation | Built-in |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 560 mm |
| External dimensions, width | 235 mm |
| External dimensions, height | 325 mm |
| Weight without accessories | 8.9 kg |
| Standards | IEC 60974-5, 10 |
X3 Wire Feeder HD200 — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6.3 A |
| Idle power | 6 W |
| Welding current 60% | 450 A |
| Welding current 100% | 380 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 2 mm |
| Filler wire diameter, Al | 0.8 ... 2.4 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum wire spool weight | 5 kg |
| Maximum wire spool diameter | 200 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Control panel, display | LCD |
| Control panel, controls | 2 control knobs, Push buttons |
| Control panel, type of installation | Built-in |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 560 mm |
| External dimensions, width | 235 mm |
| External dimensions, height | 325 mm |
| Weight without accessories | 8.9 kg |
| Standards | IEC 60974-5, 10 |
X3 Wire Feeder HD300 Rotameter — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6.3 A |
| Idle power | 6 W |
| Welding current 60% | 450 A |
| Welding current 100% | 380 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 2 mm |
| Filler wire diameter, Ss | 0.8 ... 2 mm |
| Filler wire diameter, MC/FC | 0.8 ... 2.4 mm |
| Filler wire diameter, Al | 0.8 ... 2.4 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum wire spool weight | 20 kg |
| Maximum wire spool diameter | 300 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Control panel, display | LCD |
| Control panel, controls | 2 control knobs, Push buttons |
| Control panel, type of installation | Built-in |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 670 mm |
| External dimensions, width | 240 mm |
| External dimensions, height | 465 mm |
| Weight without accessories | 14.4 kg |
| Standards | IEC 60974-5, 10 |
X3 Wire Feeder HD300 — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6.3 A |
| Idle power | 6 W |
| Welding current 60% | 450 A |
| Welding current 100% | 380 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 2 mm |
| Filler wire diameter, Ss | 0.8 ... 2 mm |
| Filler wire diameter, MC/FC | 0.8 ... 2.4 mm |
| Filler wire diameter, Al | 0.8 ... 2.4 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum wire spool weight | 20 kg |
| Maximum wire spool diameter | 300 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Control panel, display | LCD |
| Control panel, controls | 2 control knobs, Push buttons |
| Control panel, type of installation | Built-in |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 670 mm |
| External dimensions, width | 240 mm |
| External dimensions, height | 465 mm |
| Weight without accessories | 14.4 kg |
| Standards | IEC 60974-5, 10 |
X3P Power Source Pulse 400 WM — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 28 ... 25 A |
| Effective supply current [I1eff] | 23 ... 19 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 21 W |
| No-load voltage [U0] | 60 ... 75 V |
| Output at +40 °C, rated max current, MIG | 400 A |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output at +40 °C, 100% MIG (@MV low range) | 300 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Output range, MIG (@MV low range) | 15 A / 10 V ... 400 A / 50 V |
| Output range, MMA (@MV low range) | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| VRD voltage | 24 V |
| Power factor at rated maximum current [λ] | 0.8 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 2.9 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 30 kVA |
| Cooling power at 1 l/min | 1 kW |
| Recommended coolant | MGP 4456 |
| Maximum coolant pressure | 0.4 MPa |
| Tank volume | 3 l |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 703 mm |
| Weight without accessories | 58.2 kg |
| Standards | IEC 60974-1, -2, -10 |
X3P Power Source Pulse 400 GM — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 28 ... 25 A |
| Effective supply current [I1eff] | 23 ... 19 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 21 W |
| No-load voltage [U0] | 60 ... 75 V |
| Output at +40 °C, rated max current, MIG | 400 A |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output at +40 °C, 100% MIG (@MV low range) | 300 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Output range, MIG (@MV low range) | 15 A / 10 V ... 400 A / 50 V |
| Output range, MMA (@MV low range) | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| VRD voltage | 24 V |
| Power factor at rated maximum current [λ] | 0.8 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 2.9 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 30 kVA |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 451 mm |
| Weight without accessories | 41 kg |
| Standards | IEC 60974-1, -10 |
X3S Power Source Syn 400 WM — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 31 ... 23 A |
| Effective supply current [I1eff] | 24 ... 18 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 21 W |
| No-load voltage [U0] | 55 ... 67 V |
| Output at +40 °C, rated max current, MIG | 400 A |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output at +40 °C, 100% MIG (@MV low range) | 300 A |
| Output range, MIG | 15 A / 12 V ... 400 A / 40 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 41 V |
| Output range, MIG (@MV low range) | 15 A / 12 V ... 400 A / 40 V |
| Output range, MMA (@MV low range) | 15 A / 10 V ... 400 A / 41 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| VRD voltage | 24 V |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 2.4 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Cooling power at 1 l/min | 1 kW |
| Recommended coolant | MGP 4456 |
| Maximum coolant pressure | 0.4 MPa |
| Tank volume | 3 l |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 703 mm |
| Weight without accessories | 57 kg |
| Standards | IEC 60974-1, -2, -10 |
X3S Power Source Syn 400 GM — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 31 ... 23 A |
| Effective supply current [I1eff] | 24 ... 18 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 21 W |
| No-load voltage [U0] | 55 ... 67 V |
| Output at +40 °C, rated max current, MIG | 400 A |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output at +40 °C, 100% MIG (@MV low range) | 300 A |
| Output range, MIG | 15 A / 12 V ... 400 A / 40 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 41 V |
| Output range, MIG (@MV low range) | 15 A / 12 V ... 400 A / 40 V |
| Output range, MMA (@MV low range) | 15 A / 10 V ... 400 A / 41 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| VRD voltage | 24 V |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 2.4 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 451 mm |
| Weight without accessories | 39.7 kg |
| Standards | IEC 60974-1, -10 |
X3P Power Source Pulse 450 W — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...415 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 33 ... 30 A |
| Effective supply current [I1eff] | 25 ... 23 A |
| Rated maximum input power [S1max] | 21 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 15 W |
| No-load voltage [U0] | 61 ... 67 V |
| Open circuit voltage [Uav] | 60 ... 65 V |
| Output at +40 °C, 60% MIG | 450 A |
| Output at +40 °C, 100% MIG | 380 A |
| Output at +40 °C, 60% MMA | 430 A |
| Output at +40 °C, 100% MMA | 360 A |
| Output range, MIG | 15 A / 12 V ... 450 A / 45 V |
| Output range, MMA | 15 A / 15 V ... 430 A / 46 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| VRD voltage | 24 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 87 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Cooling power at 1 l/min | 1.2 kW |
| Recommended coolant | MGP 4456 (Kemppi mixture) |
| Maximum coolant pressure | 0.4 MPa |
| Tank volume | 3 l |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 613 mm |
| Weight without accessories | 47 kg |
| Standards | IEC 60974-1, -2, -10 |
X3P Power Source Pulse 450 G — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...415 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 33 ... 30 A |
| Effective supply current [I1eff] | 25 ... 23 A |
| Rated maximum input power [S1max] | 21 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 15 W |
| No-load voltage [U0] | 61 ... 67 V |
| Open circuit voltage [Uav] | 60 ... 65 V |
| Output at +40 °C, 60% MIG | 450 A |
| Output at +40 °C, 100% MIG | 380 A |
| Output at +40 °C, 60% MMA | 430 A |
| Output at +40 °C, 100% MMA | 360 A |
| Output range, MIG | 15 A / 12 V ... 450 A / 45 V |
| Output range, MMA | 15 A / 15 V ... 430 A / 46 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| VRD voltage | 24 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 87 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 361 mm |
| Weight without accessories | 35 kg |
| Standards | IEC 60974-1, -10 |
X3S Power Source Syn 420 W — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...415 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 29 ... 27 A |
| Effective supply current [I1eff] | 23 ... 21 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 15 W |
| No-load voltage [U0] | 54 ... 59 V |
| Open circuit voltage [Uav] | 54 ... 59 V |
| Output at +40 °C, 60% MIG | 420 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 330 A |
| Output range, MIG | 15 A / 12 V ... 420 A / 40 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 41 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.85 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Cooling power at 1 l/min | 1.2 kW |
| Recommended coolant | MGP 4456 (Kemppi mixture) |
| Maximum coolant pressure | 0.4 MPa |
| Tank volume | 3 l |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 613 mm |
| Weight without accessories | 47 kg |
| Standards | IEC 60974-1, -2, -10 |
X3S Power Source Syn 420 G — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...415 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 29 ... 27 A |
| Effective supply current [I1eff] | 23 ... 21 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 15 W |
| No-load voltage [U0] | 54 ... 59 V |
| Open circuit voltage [Uav] | 54 ... 59 V |
| Output at +40 °C, 60% MIG | 420 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output at +40 °C, 60% MMA | 400 A |
| Output at +40 °C, 100% MMA | 330 A |
| Output range, MIG | 15 A / 12 V ... 420 A / 40 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 41 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.85 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6 MVA |
| Voltage supply for auxiliary devices | 48 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 698 mm |
| External dimensions, width | 251 mm |
| External dimensions, height | 361 mm |
| Weight without accessories | 35 kg |
| Standards | IEC 60974-1, -10 |
GX 405WS 8m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 300 A |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 134 mm |
| Neck dimensions: height | 100 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 8 m |
| Remote control | GXR10 (optional) |
| Standards | IEC 60974-7 |
GXe 405G 5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Air |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 35% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Rotating |
| Neck dimensions: length | 149 mm |
| Neck dimensions: height | 96 mm |
| Neck dimensions: angle | 50 ° |
| Welding torch cable length | 5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GXe 405G 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Air |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 35% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Rotating |
| Neck dimensions: length | 149 mm |
| Neck dimensions: height | 96 mm |
| Neck dimensions: angle | 50 ° |
| Welding torch cable length | 3.5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GXe 505W 5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 163 mm |
| Neck dimensions: height | 105 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GXe 305W 5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 300 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.2 mm |
| Load capacity test, stick out length | 18 mm |
| Load capacity test, gas flow | 15 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 126 mm |
| Neck dimensions: height | 93 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GX305GS 8m — Technical data
| Description | Value |
|---|---|
| Welding torch cable length | 8 m |
GXe 405W 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 144 mm |
| Neck dimensions: height | 99 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 3.5 m |
| Remote control | Optional |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GXe 405W 5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 144 mm |
| Neck dimensions: height | 99 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GXe 505W 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Load capacity test, gas flow | 20 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 163 mm |
| Neck dimensions: height | 105 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 3.5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GX 305GMN 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Air |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 35% / Ar + 18% CO₂ | 350 A |
| Load capacity test, filler wire diameter | 1.2 mm |
| Load capacity test, stick out length | 18 mm |
| Load capacity test, gas flow | 15 l/min |
| Gun handle | Yes |
| Neck type | Changeable, Rotating |
| Neck dimensions: length | 117 mm |
| Neck dimensions: height | 97 mm |
| Neck dimensions: angle | 50 ° |
| Welding torch cable length | 3.5 m |
| Remote control | GXR10 (optional) |
| Standards | IEC 60974-7 |
GXe 305G 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Air |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 35% / Ar + 18% CO₂ | 300 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.2 mm |
| Load capacity test, stick out length | 18 mm |
| Load capacity test, gas flow | 15 l/min |
| Gun handle | Yes |
| Neck type | Rotating |
| Neck dimensions: length | 135 mm |
| Neck dimensions: height | 96 mm |
| Neck dimensions: angle | 50 ° |
| Welding torch cable length | 3.5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |
GXe 305W 3.5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 100% / Ar + 18% CO₂ | 300 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.2 mm |
| Load capacity test, stick out length | 18 mm |
| Load capacity test, gas flow | 15 l/min |
| Gun handle | Yes |
| Neck type | Standard |
| Neck dimensions: length | 126 mm |
| Neck dimensions: height | 93 mm |
| Neck dimensions: angle | 48 ° |
| Welding torch cable length | 3.5 m |
| Remote control | Optional |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GXe 305G 5m — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Type of cooling | Air |
| Contact tip | M10x1 |
| Method of guidance | Manual |
| Load capacity 35% / Ar + 18% CO₂ | 300 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.2 mm |
| Load capacity test, stick out length | 18 mm |
| Load capacity test, gas flow | 15 l/min |
| Gun handle | Yes |
| Neck type | Rotating |
| Neck dimensions: length | 135 mm |
| Neck dimensions: height | 96 mm |
| Neck dimensions: angle | 50 ° |
| Welding torch cable length | 5 m |
| Remote control | Optional |
| Standards | IEC 60974-7 |