- Home
- Robotic Welding
- AX MIG Welder
Simple integration, fast setup
After just a few hours of setup work, AX MIG Welder is ready for welding.
Ease of use
Clear and simple, web browser-based user interface with Weld Assist guidance tool for up to 60 % faster setup of optimal welding parameters.
High performance, low maintenance
430 A @ ED 100 % and MAX or Wise welding processes optimized for robotic welding elevate productivity.
Traceable high-performance robotic welding
The Kemppi AX MIG Welder brings powerful performance and maximum productivity potential to your robotic welding system. Enjoy easy integration and ensure repeatable, high-quality welds with high-performance arc welding applications.
With a 400 or 500 A power source and robotic wire feeder, the AX MIG Welder thrives in 24/7 high-intensity automated welding applications. Need more? Activate MAX or Wise arc performance welding processes to increase speed, lower heat input, and increase penetration for challenging robotic welding applications or demanding production targets. MAX and Wise processes are optimized for robotic welding applications.
The AX MIG Welder is easy to integrate into your robotic welding system. With a comprehensive set of connectivity options, it offers new ways to get the most out of your arc welding robot. The AX MIG Welder has an intuitive remote control user interface designed by the world’s leading UX team. It’s easy to use and can be accessed anywhere on your laptop or mobile device through a web browser.
Weld Assist helps anyone quickly find the correct welding parameters. WeldEye Quality Management offers 100% traceability, WPS compliance, and faster documentation. In addition, you can manage welding procedure specifications, welding personnel, their qualifications, and your entire production fleet anywhere in the world. The welder or operator can provide updates on their welding activities, including details about the WPS, wire type, and gas. They can also inform when they have finished specific welds and completed work orders.
WeldEye ArcVision offers monitoring and transparent reporting on key robotic welding performance metrics for lighter monitoring. With a three-month trial, you can try the WeldEye ArcVision and the Welding Procedures module free of charge.
Ensure repeatable, high-quality welds from your arc welding robot with fine-tuned ignition and a precise seam tracking signal. Touch Sense is used to determine the location of the weld seam in relation to the robot, and the Through Arc Seam Tracking (TAST) feature helps the robotic welding system correct the welding path if there are deviations in the joint. There is also a Gas Flow Sensor and Collision Detection.
Adding an AX MIG Welder to your robotic welding system is easy. It’s the best way to get high-quality automated welds and the latest welding connectivity features.
AX MIG Welder – Robotic welding machine
Traceable high-performance robotic welding
Looking for more options?
Open the detailed configurator hereVideos
GX-R Torch Adjuster W — Technical data
| Description | Value |
|---|---|
| Type of cooling | Liquid |
X-R Flange 56 - 8 - M4 #19 — Technical data
| Description | Value |
|---|---|
| Weight | 138 g |
X-R Flange 58 - 6 - M4 #22 — Technical data
| Description | Value |
|---|---|
| Weight | 116 g |
X-R Flange 31,5 - 4 - M5 #17 — Technical data
| Description | Value |
|---|---|
| Weight | 191 g |
X-R Flange 40 - 4 - M6 #15 — Technical data
| Description | Value |
|---|---|
| Weight | 202 g |
X-R Flange 31,5 - 4 - M5 #23 — Technical data
| Description | Value |
|---|---|
| Weight | 228 g |
GX-R Wire Brake G — Technical data
| Description | Value |
|---|---|
| Type of cooling | Air |
| Rating of electrical components (remote, nominal) | 24 V |
| Weight | 955 g |
X-R Flange 80 - 6 - M8 #12 — Technical data
| Description | Value |
|---|---|
| Weight | 207 g |
X-R Sensor T1 — Technical data
| Description | Value |
|---|---|
| Remote control | Yes |
| Rating of electrical components (remote, nominal) | 24 V |
| Rating of electrical components (remote, nominal) | 10 mA |
| Weight | 1306 g |
X-R Sensor T2 — Technical data
| Description | Value |
|---|---|
| Remote control | Yes |
| Rating of electrical components (remote, nominal) | 24 V |
| Rating of electrical components (remote, nominal) | 10 mA |
| Weight | 1457 g |
X-R Holder — Technical data
| Description | Value |
|---|---|
| Weight | 0.19 kg |
X-R Bracket M — Technical data
| Description | Value |
|---|---|
| Weight | 0.5 kg |
X-R Bracket S — Technical data
| Description | Value |
|---|---|
| Weight | 0.43 kg |
GX-R Wire Brake W — Technical data
| Description | Value |
|---|---|
| Type of cooling | Liquid |
| Rating of electrical components (remote, nominal) | 24 V |
| Weight | 902 g |
X-R Flange 63 - 4 - M6 #27 — Technical data
| Description | Value |
|---|---|
| Weight | 130 g |
X-R Flange 45 - 4 - M6 #25 — Technical data
| Description | Value |
|---|---|
| Weight | 201 g |
X-R Flange 40 - 4 - M6 #24 — Technical data
| Description | Value |
|---|---|
| Weight | 199 g |
X-R Flange 56 - 8 - M4 #21 — Technical data
| Description | Value |
|---|---|
| Weight | 138 g |
X-R Flange 36 - 6 - M4 #20 — Technical data
| Description | Value |
|---|---|
| Weight | 186 g |
X-R Flange 64 - 8 - M4 #18 — Technical data
| Description | Value |
|---|---|
| Weight | 134 g |
X-R Flange 100 - 6 - M10 #14 — Technical data
| Description | Value |
|---|---|
| Weight | 454 g |
X-R Flange 50 - 6 - M6 #13 — Technical data
| Description | Value |
|---|---|
| Weight | 210 g |
GX-R Torch Adjuster G — Technical data
| Description | Value |
|---|---|
| Type of cooling | Air |
GX-R Cable T2 G 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1600mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1600mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1000mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1000mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1480mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S G 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 S W 1480mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 960mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1560mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1360mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 2160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1440mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Air |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1320mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1520mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 960mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1560mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1320mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1280mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 G 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 2240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 2160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1520mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1200mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1160mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 G 1040mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1360mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1280mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T2 W 1080mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 2240mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1440mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1400mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1200mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
GX-R Cable T1 W 1120mm — Technical data
| Description | Value |
|---|---|
| Welding connection type | Euro |
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Type of cooling | Liquid |
| Cooling power at 1 l/min | 0.9 kW |
| Minimum coolant flow rate | 1 l/min |
| Maximum coolant pressure | 5 Bar |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Standards | IEC 60974-7 |
R500 Wire Feeder LH EUR+ — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6 A |
| Welding current 60% | 500 A |
| Welding current 100% | 430 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Twin-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, MC/FC | 1 ... 1.6 mm |
| Filler wire diameter, Al | 1 ... 1.6 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum shielding gas pressure | 0.5 MPa |
| Maximum air blow pressure | 0.8 MPa |
| Air blow rate | 0.24 m³/h |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 374 mm |
| External dimensions, width | 234 mm |
| External dimensions, height | 183 mm |
| Weight without accessories | 6.75 kg |
| Standards | IEC 60974-5, -10 |
R500 Wire Feeder HD EUR+ — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Welding current 60% | 500 A |
| Welding current 100% | 430 A |
| EMC class | A |
| Welding connection type | Euro, Euro+Amphenol |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, MC/FC | 1 ... 1.6 mm |
| Filler wire diameter, Al | 1 ... 1.6 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Maximum shielding gas pressure | 0.5 MPa |
| Maximum air blow pressure | 0.8 MPa |
| Air blow rate | 0.265 m³/h |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 329.62 mm |
| External dimensions, width | 234.1 mm |
| External dimensions, height | 159.2 mm |
| Weight without accessories | 4.73 kg |
| Standards | IEC 60974-5, -10 |
RA50 4R Assistive Wire Feeder — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| EMC class | A |
| Wire feed mechanism | 4-roll, Single-motor |
| Diameter of feed rolls | 32 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, MC/FC | 1 ... 1.6 mm |
| Filler wire diameter, Al | 1 ... 1.6 mm |
| Wire feed speed | 0.5 ... 25 m/min |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| External dimensions, length | 374 mm |
| External dimensions, width | 234 mm |
| External dimensions, height | 183 mm |
| Weight without accessories | 4.5 kg |
R500 Wire Feeder RH EUR+ — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6 A |
| Welding current 60% | 500 A |
| Welding current 100% | 430 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Twin-motor |
| Diameter of feed rolls | 32 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Maximum air blow pressure | 0.8 MPa |
| Air blow rate | 0.24 m³/h |
| Wired communication type | CAN bus |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 374 mm |
| External dimensions, width | 234 mm |
| External dimensions, height | 183 mm |
| Weight without accessories | 6.75 kg |
| Standards | IEC 60974-5, -10 |
R500 Wire Feeder EUR — Technical data
| Description | Value |
|---|---|
| Supply voltage | 48 V |
| Supply current at maximum load | 6 A |
| Welding current 60% | 500 A |
| Welding current 100% | 430 A |
| EMC class | A |
| Welding connection type | Euro |
| Wire feed mechanism | 4-roll, Twin-motor |
| Diameter of feed rolls | 32 mm |
| Maximum shielding gas pressure | 0.5 MPa |
| Wired communication type | CAN bus |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 374 mm |
| External dimensions, width | 234 mm |
| External dimensions, height | 183 mm |
| Weight without accessories | 6.15 kg |
| Standards | IEC 60974-5, -10 |
X5 Power Source 400 — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 24 A |
| Effective supply current [I1eff] | 24 ... 21 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 30 W |
| No-load state power consumption (MMA), power save | 30 W |
| No-load state power consumption (MMA), fans ON | 175 W |
| No-load voltage [U0] | 52 ... 67 V |
| Open circuit voltage [Uav] | 52 ... 67 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 12 V ... 400 A / 42 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 42 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 42 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 90 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 5.8 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 MV WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 24 ... 28 A |
| Effective supply current [I1eff] | 19 ... 23 A |
| Rated maximum input power [S1max] | 19 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 30 W |
| No-load voltage [U0] | 52 ... 67 V |
| Open circuit voltage [Uav] | 52 ... 67 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output at +40 °C, 100% MIG (@MV low range) | 300 A |
| Output range, MIG | 15 A / 12 V ... 400 A / 42 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 42 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 42 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 90 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 5.8 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Voltage supply for cooling unit (MV low range) | 220...230 V, 24 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 43.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 38 ... 33 A |
| Effective supply current [I1eff] | 31 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 30 W |
| No-load state power consumption (MMA), power save | 30 W |
| No-load state power consumption (MMA), fans ON | 195 W |
| No-load voltage [U0] | 59 ... 75 V |
| Open circuit voltage [Uav] | 59 ... 75 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 430 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 47 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 47 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 47 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 90 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.4 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 38 ... 33 A |
| Effective supply current [I1eff] | 31 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 30 W |
| No-load state power consumption (MMA), power save | 30 W |
| No-load state power consumption (MMA), fans ON | 195 W |
| No-load voltage [U0] | 59 ... 75 V |
| Open circuit voltage [Uav] | 59 ... 75 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 430 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 47 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 47 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 47 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 90 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.4 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 Pulse+ — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 26 A |
| Effective supply current [I1eff] | 24 ... 22 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.86 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 Pulse+ WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 26 A |
| Effective supply current [I1eff] | 24 ... 22 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.86 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 24 A |
| Effective supply current [I1eff] | 24 ... 21 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 30 W |
| No-load state power consumption (MMA), power save | 30 W |
| No-load state power consumption (MMA), fans ON | 175 W |
| No-load voltage [U0] | 52 ... 67 V |
| Open circuit voltage [Uav] | 52 ... 67 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 12 V ... 400 A / 42 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 42 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 42 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.88 |
| Efficiency at rated maximum current [η] | 90 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 5.8 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 Pulse WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 39 ... 34 A |
| Effective supply current [I1eff] | 30 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 31 W |
| No-load state power consumption (MMA), power save | 32 W |
| No-load state power consumption (MMA), fans ON | 240 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 400 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.7 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 Pulse — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 39 ... 34 A |
| Effective supply current [I1eff] | 30 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 31 W |
| No-load state power consumption (MMA), power save | 32 W |
| No-load state power consumption (MMA), fans ON | 240 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 400 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.7 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 Pulse WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 26 A |
| Effective supply current [I1eff] | 24 ... 22 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 31 W |
| No-load state power consumption (MMA), power save | 32 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.85 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 Pulse — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 4 mm² |
| Maximum supply current [I1max] | 28 ... 26 A |
| Effective supply current [I1eff] | 24 ... 22 A |
| Rated maximum input power [S1max] | 20 kVA |
| Mains fuse | 25 A |
| Idle state power consumption [P1idle] | 31 W |
| No-load state power consumption (MMA), power save | 32 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.85 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 Pulse+ WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 39 ... 34 A |
| Effective supply current [I1eff] | 30 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 240 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 400 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 88 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.7 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 500 Pulse+ — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 39 ... 34 A |
| Effective supply current [I1eff] | 30 ... 27 A |
| Rated maximum input power [S1max] | 27 kVA |
| Mains fuse | 32 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 240 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 500 A |
| Output at +40 °C, 100% MIG | 400 A |
| Output range, MIG | 15 A / 10 V ... 500 A / 50 V |
| Output range, TIG | 15 A / 1 V ... 500 A / 50 V |
| Output range, MMA | 15 A / 10 V ... 500 A / 50 V |
| Voltage adjustment range, MIG | 8 ... 50 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 88 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 6.7 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 35 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 39.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 MV Pulse+ WP — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 28 ... 24 A |
| Effective supply current [I1eff] | 22 ... 19 A |
| Rated maximum input power [S1max] | 19 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 45 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 45 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 45 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 5.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Voltage supply for cooling unit (MV low range) | 220...230 V, 24 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 43.5 kg |
| Standards | IEC 60974-1, -10 |
X5 Power Source 400 MV Pulse+ — Technical data
| Description | Value |
|---|---|
| Mains connection voltage | 380...460 V ±10 % |
| Mains connection voltage (MV low range) | 220...230 V ±10 % |
| Mains connection phases | 3~50/60 Hz |
| Mains connection cable type | H07RN-F |
| Mains connection cable size | 6 mm² |
| Maximum supply current [I1max] | 28 ... 24 A |
| Effective supply current [I1eff] | 22 ... 19 A |
| Rated maximum input power [S1max] | 19 kVA |
| Mains fuse | 25 A |
| Mains fuse (@MV low range) | 32 A |
| Idle state power consumption [P1idle] | 33 W |
| No-load state power consumption (MMA), power save | 34 W |
| No-load state power consumption (MMA), fans ON | 230 W |
| No-load voltage [U0] | 76 ... 94 V |
| Open circuit voltage [Uav] | 76 ... 94 V |
| Output at +40 °C, 60% MIG | 400 A |
| Output at +40 °C, 100% MIG | 350 A |
| Output, duty cycle % at rated max. current, MIG (@MV low range) | 40 % |
| Output at +40 °C, rated max current, MIG (@MV low range) | 400 A |
| Output range, MIG | 15 A / 10 V ... 400 A / 45 V |
| Output range, TIG | 15 A / 1 V ... 400 A / 45 V |
| Output range, MMA | 15 A / 10 V ... 400 A / 45 V |
| Voltage adjustment range, MIG | 8 ... 45 V |
| Power factor at rated maximum current [λ] | 0.89 |
| Efficiency at rated maximum current [η] | 89 % |
| EMC class | A |
| Minimum short-circuit power of supply network [Ssc] | 5.3 MVA |
| Voltage supply for auxiliary devices | 12 V, 48 V |
| Voltage supply for cooling unit | 24 V, 380...460 V |
| Voltage supply for cooling unit (MV low range) | 220...230 V, 24 V |
| Wired communication type | CAN bus |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Recommended minimum generator power [Sgen] | 25 kVA |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 750 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 456 mm |
| Weight without accessories | 43.5 kg |
| Standards | IEC 60974-1, -10 |
GX-R Torch 500W S50 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 442.2 mm |
| Neck dimensions: height | 7.6 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 368 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 468 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| Neck type | Changeable |
| Neck dimensions: length | 243.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| LED light | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 442.2 mm |
| Neck dimensions: height | 7.6 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 350.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 440mm 30D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 450.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 30 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 432.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 440mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 443.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 456.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 1004 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 432.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 443.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 456.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 440mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 468 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 332.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 35D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 343.6 mm |
| Neck dimensions: height | 84.6 mm |
| Neck dimensions: angle | 35 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 356.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 803 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 232.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G 240mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 256.9 mm |
| Neck dimensions: height | 59.8 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 240mm 0D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 268 mm |
| Neck dimensions: height | 0 mm |
| Neck dimensions: angle | 0 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 651 g |
| Standards | IEC 60974-7 |
GX-R Torch 500W S50 340mm 22D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 350.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 22 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 500 W 340mm 45D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.8 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Liquid |
| Minimum coolant flow rate | 1 l/min |
| Minimum cooling power at 1 l/min | 0.9 kW |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 500 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable |
| Neck dimensions: length | 332.3 mm |
| Neck dimensions: height | 98.2 mm |
| Neck dimensions: angle | 45 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 838 g |
| Standards | IEC 60974-7 |
GX-R Torch 400G S50 440mm 30D — Technical data
| Description | Value |
|---|---|
| Filler wire diameter, Fe | 0.8 ... 1.6 mm |
| Filler wire diameter, Fe-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Ss | 0.8 ... 1.6 mm |
| Filler wire diameter, Ss-MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, MC/FC | 0.9 ... 1.6 mm |
| Filler wire diameter, Al | 0.8 ... 1.6 mm |
| Type of cooling | Air |
| Contact tip | M10X1 |
| Method of guidance | Mechanical |
| Load capacity 100% / Ar + 18% CO₂ | 400 A |
| Load capacity test, filler wire material | Fe |
| Load capacity test, filler wire diameter | 1.6 mm |
| Load capacity test, stick out length | 22 mm |
| LED light | No |
| Neck type | Changeable, Double bend |
| Neck dimensions: length | 450.5 mm |
| Neck dimensions: height | 5.7 mm |
| Neck dimensions: angle | 30 ° |
| Remote control | No |
| Operating temperature | -20 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Weight | 950 g |
| Standards | IEC 60974-7 |
X5 Cooler 1400 — Technical data
| Description | Value |
|---|---|
| Supply voltage | 380...460 V ±10 % |
| EMC class | A |
| Tank volume | 3 l |
| Cooling power at 1 l/min | 1.4 kW |
| Maximum coolant pressure | 0.4 MPa |
| Recommended coolant | MGP 4456 |
| Operating temperature | -10 ... 40 °C |
| Storage temperature | -40 ... 60 °C |
| Degree of protection (fully installed) | IP23S |
| External dimensions, length | 730 mm |
| External dimensions, width | 263 mm |
| External dimensions, height | 288 mm |
| Weight without accessories | 15 kg |
| Standards | IEC 60974-2, -10 |
Robot Connectivity Module Plus — Technical data
| Description | Value |
|---|---|
| Supply voltage | 12...48 V |
| Fuse (slow) | 0.63 A |
| Maximum touch sensing voltage [Uvs] | 200 V |
| Maximum touch sensing current [Ivs] | 20 mA |
| - Voltage at maximum touch sensing current | 113 V |
| USB voltage | 5 V |
| USB maximum current | 0.5 A |
| Maximum power consumption | 30 W |
| EMC class | A |
| Wired communication type | CAN bus, Ethernet, USB |
| Ethernet cable | RJ45 (CAT-5 or better shielded) |
| Wireless communication type | WLAN |
| WLAN type | IEEE 802.11 ac/a/b/g/n |
| Transmitter frequency and power, WLAN | 2.4 GHz: 2.412...2.484 GHz; 5.1 GHz: 5.150...5.240 GHz, 5.250...5.350 GHz, 5.470...5.725 GHz; 9...16 dBm |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 597 mm |
| External dimensions, width | 241 mm |
| External dimensions, height | 137 mm |
| Weight without accessories | 4.1 kg |
| Standards | IEC 60974-5, -10 (where applicable, together with the power source) |
Robot Connectivity Module — Technical data
| Description | Value |
|---|---|
| Supply voltage | 12...48 V |
| Fuse (slow) | 0.63 A |
| Maximum touch sensing voltage [Uvs] | 200 V |
| Maximum touch sensing current [Ivs] | 20 mA |
| - Voltage at maximum touch sensing current | 113 V |
| USB voltage | 5 V |
| USB maximum current | 0.5 A |
| Maximum power consumption | 30 W |
| EMC class | A |
| Wired communication type | CAN bus |
| Ethernet cable | RJ45 (CAT-5 or better shielded) |
| Degree of protection (fully installed) | IP23 |
| External dimensions, length | 597 mm |
| External dimensions, width | 241 mm |
| External dimensions, height | 137 mm |
| Weight without accessories | 4.1 kg |
| Standards | IEC 60974-5, -10 (where applicable, together with the power source) |